EMB-H Series
New Product
170VDC Constant Output Emergency Battery
170VDC Constant Output, Red Metal Casing with 13” Metal Flex (1/2” NPSM connector included).
Resources
ELECTRICAL (120~347V Input)
Universal Input: 100 ~ 347V AC, 50/60Hz
Input Current: 200mA
Recharge Power: 12W
Output Voltage: 170V DC
AUX Output: 12V DC = 0.2A
Surge Protection: Line-Neutral 3KV
Emergency Power: 8W / 18W / 25W / 40W
Self Diagnostic Li-ion Battery
Operating Temperature: 0°C ~ 50°C (32°F ~ 122°F)
Recharge Time: 24 Hours
Discharge Time: 90 Mins
Smart battery built-in over temperature, over charge, over discharge protections.
ELECTRICAL (277~480V Input)
High Voltage Input: 277 ~ 480V AC, 50/60Hz
Input Current: 200mA
Recharge Power: 12W
Output Voltage: 310 ~ 500V DC
AUX Output: 12V DC = 0.2A
Surge Protection: Line-Neutral 3KV
Emergency Power: 20W / 40W
Self Diagnostic Li-ion Battery
Operating Temperature: 0°C ~ 50°C (32°F ~ 122°F)
Recharge Time: 24 Hours
Discharge Time: 90 Mins
Smart battery built-in over temperature, over charge, over discharge protections.
SELF-TESTING
The integrated Self-Diagnostic circuitry will automatically conduct monthly 30s and annual 90mins tests to verify proper emergency capability per Life Safety Code requirements.
NFPA 101, Life Safety Code Outlines the following schedule:
Universal Input: 100 ~ 347V AC, 50/60Hz
Input Current: 200mA
Recharge Power: 12W
Output Voltage: 170V DC
AUX Output: 12V DC = 0.2A
Surge Protection: Line-Neutral 3KV
Emergency Power: 8W / 18W / 25W / 40W
Self Diagnostic Li-ion Battery
Operating Temperature: 0°C ~ 50°C (32°F ~ 122°F)
Recharge Time: 24 Hours
Discharge Time: 90 Mins
Smart battery built-in over temperature, over charge, over discharge protections.
ELECTRICAL (277~480V Input)
High Voltage Input: 277 ~ 480V AC, 50/60Hz
Input Current: 200mA
Recharge Power: 12W
Output Voltage: 310 ~ 500V DC
AUX Output: 12V DC = 0.2A
Surge Protection: Line-Neutral 3KV
Emergency Power: 20W / 40W
Self Diagnostic Li-ion Battery
Operating Temperature: 0°C ~ 50°C (32°F ~ 122°F)
Recharge Time: 24 Hours
Discharge Time: 90 Mins
Smart battery built-in over temperature, over charge, over discharge protections.
SELF-TESTING
The integrated Self-Diagnostic circuitry will automatically conduct monthly 30s and annual 90mins tests to verify proper emergency capability per Life Safety Code requirements.
NFPA 101, Life Safety Code Outlines the following schedule:
- Monthly - During AC mode, the system conducts a 30s self-discharge test of the emergency led driver every 30 days and automatically restore to normal charging after 30s discharged.
- Annually - During AC mode, the system conducts a 90mins self-discharge test of the emergency led driver every 365 days and automatically restore to normal charging after fully discharged.
CERTIFICATION
UL924 Certified and Listed.
CEC T20 Certified and Listed.
WARRANTY
5 year warranty, see Limited Warranty for additional information.
Emergency Options
- Emergency Battery Backup
- Remote EM Battery
Listings
- cULus
Special Programs
- Quick Ship
Voltage
- 100-347 V
- 277-480 V
Warranty
- 5 yr
Watts
- 8 w
- 18 w
- 20 w
- 25 w
- 40 w